Application — Defense equipment power
Requirement — The challenge was to handle AC220V mains power within one pack in the defense equipment power system.
Solution — We built an AC220V 2kW inverter into a LiFePO4 4S pack (DC 12.8V, 3,840Wh).
Result — The integrated build in an approx. 60kg housing met the defense equipment power specification.
If you are considering a custom build to a similar specification, submit a requirements sheet. Our engineer will review it and respond.
Specification
Specifications
| Product Code | DMOP-LF3840Wh-AC2000-DC128 |
|---|
General
| Model | DMOP-LF3840Wh-AC2000-DC128 |
|---|---|
| Dimension | Approx. L497.5 x W606.3 x H156mm (including protrusions) |
| Weight | Approx. 60kg |
Battery ① Electrical specifications
| Battery Type | 4S LiFePO₄ |
|---|---|
| Nominal Voltage | 12.8V (11.2–14.6V) |
| Nominal Capacity | |
| Energy | 3,840Wh |
| Max Discharge Power | |
| Charging Method | CC-CV(Constant Voltage with Limited Current) |
| Standard Charging Condition (0.2C) | 14.6V±1%, 60A, CC-CVEnd Current : 6A (0.02C) |
| Max Charging Condition | 14.6V±1%, 150A, CC-CVEnd Current : 6A (0.02C) |
| Standard Discharge Current | |
| Max Discharge Current | |
| Instantaneous Discharge Current | |
| Discharge Cut-off Voltage | 11.2V2.8V per cell |
| AC output | AC 220V – 2,000W(60Hz) (Surge 3,000W ≤ 1.5Sec) |
| DC output | 12.8Vdc (SOC 0-100% : 11.2 – 14.6Vdc) Max ≤150A, (Peak 300A ≤1.5 sec) |
Battery ② Operation · Safety
| Max Temperature Range | Charging: 0 – +45°C Discharging: -20 – +55°C Storage (recommended): +5 – +30°C |
|---|---|
| Battery Management System | Module configuration: 6P Overcharge cutoff: 3.70–3.90V±25mV per cell Overcharge recovery: 3.50–3.70V±50mV per cell Over-discharge cutoff: 2.00–2.50V±25mV per cell Over-discharge recovery: 2.40–2.90V±50mV per cell Overcurrent cutoff: 135A–160A±25% per module Short-circuit protection: Yes Over-temperature cutoff: Yes Cell balancing: Yes Control method: MOSFET |
| Storage Life | Up to 6 months under no-load conditionsState of charge: SoC 60% Environment: ambient 25°C, humidity ≤70% |
| Cycle Life | ≥60% of nominal capacity after 2500 cycles Charge/discharge condition: standard charge, then discharge at the standard discharge current down to the cut-off voltage Environment: ambient 25°C, humidity ≤70% |
Terminals · Control
| Terminal configuration | |
|---|---|
| Terminal specification | |
| Fastening · Wiring | |
| Charge/discharge switch (ON/OFF) | Charge/discharge rocker switch (ON/OFF) |