Application — Defense communication equipment power

Requirement — The customer needed a power source for defense communication equipment power with 6V regulated auxiliary power.

Solution — We combined a 6V regulated DC-DC converter into a LiFePO4 4S pack (DC 12.8V, 48Ah) as a single unit.

Result — The integrated build in an approx. 6.5kg housing met the defense communication equipment power specification.

If you are considering a custom build to a similar specification, submit a requirements sheet. Our engineer will review it and respond.

Specification

Specifications

Product CodeDMOP-128LF48-B20-CV
General
ModelDMOP-128LF48-B20-CV
DimensionApprox. L310 x W242 x h80mm (including protrusions)
Approx. L310 x W215 x h80mm (excluding protrusions)
WeightApprox. 6.5kg
Battery ① Electrical specifications
Battery Type
Nominal Voltage12.8V
Nominal Capacity48.0Ah
Energy
Max Discharge Power
Charging MethodCC-CV(Constant Voltage with Limited Current)
Standard Charging Condition14.6V ±1%, 10A (0.2C)(End Current : 0.05C)
Max Charging Condition14.6V ±1%, 25A (0.5C)(End Current : 0.05C)
Standard Discharge Current
Max Discharge Current
Instantaneous Discharge Current
Discharge Cut-off Voltage11.2V2.8V per cell
DC-DC Converter OutputDC 6.0V, MAX 20A
Battery ② Operation · Safety
Operation TemperatureCharging: +10 – +45°C
Discharging: -20 – +60°C
Protection Circuit ModuleOvercharge cutoff: 3.90V ± 0.0250V per cell
Overcharge recovery: 3.80V ± 0.0250V per cell
Over-discharge cutoff: 2.00V ± 0.0625V per cell
Over-discharge recovery: 2.30V ± 0.0100V per cell
Overcurrent cutoff: 40A ± 10A
Short-circuit protection: Yes
Over-temperature cutoff: Yes
Cell balancing: Yes
Storage LifeUp to 6 months under no-load conditionsState of charge: SoC 60%
Environment: ambient 25°C, humidity ≤70%
Cycle Life≥2500cycle (70% DOD @ ≥60% of initial capacity)* This cycle life applies only under the Standard Charging and Standard Discharge Current conditions
Terminals · Control
Terminal configuration
Terminal specification
Fastening · Wiring
Charge/discharge switch (ON/OFF)