Application — Autonomous vehicle system power

Requirement — The request was to consolidate high-output discharge, 5V·12V regulated auxiliary power, and real-time status monitoring for autonomous vehicle system power into a single power unit.

Solution — We configured a LiFePO4 4S pack (DC 12.8V, 500Ah) together with 5V·12V regulated DC-DC converters and CAN communication monitoring.

Result — The integrated build in an approx. 80kg housing met the autonomous vehicle system power specification.

If you are considering a custom build to a similar specification, submit a requirements sheet. Our engineer will review it and respond.

Specification

Specifications

Product CodeDMOP-128LF500-B750-CAN-CV
General
ModelDMOP-128LF500-B750-CAN-CV
DimensionApprox. L950 x W360 x h226mm (including protrusions)
Approx. L920 x W396 x h226mm (excluding protrusions)
WeightApprox. 80kg
Battery ① Electrical specifications
Battery Type
Nominal Voltage12.8V
Nominal Capacity500.0Ah
Energy
Max Discharge Power
Charging MethodCC-CV(Constant Voltage with Limited Current)
Standard Charging Condition14.6V ±1%, 100A (0.2C)(End Current : 0.05C)
Max Charging Condition14.6V ±1%, 250A (0.5C)(End Current : 0.05C)
Standard Discharge Current
Max Discharge Current
Instantaneous Discharge Current
Discharge Cut-off Voltage11.2V2.8V per cell
DC-DC Converter OutputDC 5.0V, MAX 30ADC 12.0V, MAX 80ADC 12.0V, MAX 250A
Communication moduleCAN 2.0a(voltage, current and temperature monitoring)
Battery ② Operation · Safety
Operation TemperatureCharging: +10 – +45°C
Discharging: -20 – +60°C
Protection Circuit ModuleOvercharge cutoff: 3.90V ± 0.01V per cell
Overcharge recovery: 3.70V ± 0.05V per cell
Over-discharge cutoff: 2.00V ± 0.01V per cell
Over-discharge recovery: 2.40V ± 0.05V per cell
Overcurrent cutoff: 470A ± 30%
Short-circuit protection: Yes
Over-temperature cutoff: Yes
Cell balancing: Yes
Storage LifeUp to 6 months under no-load conditionsState of charge: SoC 60%
Environment: ambient 25°C, humidity ≤70%
Cycle Life≥2500cycle (70% DOD @ ≥60% of initial capacity)* This cycle life applies only under the Standard Charging and Standard Discharge Current conditions
Terminals · Control
Terminal configuration
Terminal specification
Fastening · Wiring
Charge/discharge switch (ON/OFF)