Skip to product information
1 of 2

POWERCRAFT

Custom Battery Pack 12.8V 614Ah · 600A BMS · onboard charging · CAN communication

Custom Battery Pack 12.8V 614Ah · 600A BMS · onboard charging · CAN communication

Custom-build quote item

Product codeDMOP-128LF614-B600-CH

Pricing is quoted individually based on your requirements (voltage, capacity, peak current, enclosure, communication and so on). The button below pre-fills the RFQ form with this product's baseline specification, so you only need to edit what differs before submitting.

Start an RFQ with these specs →
contact@devicemall.co.kr · 02-982-7070 (Mon-Fri 09:00-18:00)
View full details

Application — Autonomous vehicle system power

Requirement — The challenge was to handle high-output discharge, recharging while driving, and real-time status monitoring within one pack in the autonomous vehicle system power application.

Solution — We built an onboard charging module and CAN communication monitoring into a LiFePO4 4S pack (DC 12.8V, 614Ah).

Result — A discharge configuration rated at 300A (0.5C) maximum (400A peak @ ≤1.5s), housed in approx. 75kg, completes autonomous vehicle system power in a single pack.

If you are considering a custom build to a similar specification, submit a requirements sheet. Our engineer will review it and respond.

Specification

Specifications

Product CodeDMOP-128LF614-B600-CH
General
ModelDMOP-128LF614-B600-CH
DimensionApprox. L618 x W600 x h182mm (including protrusions)
Approx. L618 x W600 x h153mm (excluding protrusions)
WeightApprox. 75kg
Battery ① Electrical specifications
Battery Type
Nominal Voltage12.8V
Nominal Capacity614.0Ah
Energy
Max Discharge Power
Charging MethodCC-CV(Constant Voltage with Limited Current)
Standard Charging Condition14.6V ±1%, 120A (0.2C)(End Current : 0.05C)
Max Charging Condition14.6V ±1%, 300A (0.5C)(End Current : 0.05C)
Standard Discharge Current120A(0.2C)
Cont. Discharge Current300A(0.5C)
Peak Discharge Current400A ≤1.5sec
Discharge Cut-off Voltage11.2V2.8V per cell
Communication moduleCAN 2.0a(voltage, current and temperature monitoring)
Charge moduleCharging input: 12.3V–22.0V- Charging output: 14.6V 10A CC-CV
Battery ② Operation · Safety
Operation TemperatureCharging: +10 – +45°C
Discharging: -20 – +60°C
Protection Circuit ModuleOvercharge cutoff: 3.90V ± 0.01V per cell
Overcharge recovery: 3.70V ± 0.05V per cell
Over-discharge cutoff: 2.00V ± 0.01V per cell
Over-discharge recovery: 2.40V ± 0.05V per cell
Overcurrent cutoff: 470A ± 30%
Short-circuit protection: Yes
Over-temperature cutoff: Yes
Cell balancing: Yes
Storage LifeUp to 6 months under no-load conditionsState of charge: SoC 60%
Environment: ambient 25°C, humidity ≤70%
Cycle Life≥2500cycle (70% DOD @ ≥60% of initial capacity)* This cycle life applies only under the Standard Charging and Standard Discharge Current conditions
Terminals · Control
Terminal configuration
Terminal specification
Fastening · Wiring
Charge/discharge switch (ON/OFF)