Skip to product information
1 of 2

POWERCRAFT

Custom Battery Pack 25.2V 13.6Ah · 50A BMS · 24V DC-DC module

Custom Battery Pack 25.2V 13.6Ah · 50A BMS · 24V DC-DC module

Custom-build quote item

Product codeDMOP-252LI136-B50

Pricing is quoted individually based on your requirements (voltage, capacity, peak current, enclosure, communication and so on). The button below pre-fills the RFQ form with this product's baseline specification, so you only need to edit what differs before submitting.

Start an RFQ with these specs →
contact@devicemall.co.kr · 02-982-7070 (Mon-Fri 09:00-18:00)
View full details

Application — Communication equipment power

Requirement — The customer needed a power source for communication equipment power with 24V regulated auxiliary power.

Solution — We combined a 24V regulated DC-DC converter into a Li-ion 7S pack (DC 25.2V, 13.6Ah) as a single unit.

Result — The integrated build in an approx. 3kg housing met the communication equipment power specification.

If you are considering a custom build to a similar specification, submit a requirements sheet. Our engineer will review it and respond.

Specification

Specifications

Product CodeDMOP-252LI136-B50
General
ModelDMOP-252LI136-B50
DimensionApprox. L260 x W145 x H75mm (including protrusions)
WeightApprox. 3kg
Battery ① Electrical specifications
Battery Type7S Li-ion
Nominal Voltage25.2V (21.0–29.4V)
Nominal Capacity13.6Ah
EnergyApprox. 342Wh
Max Discharge Power288W
Charging MethodCC-CV(Constant Voltage with Limited Current)
Standard Charging Condition (0.2C)29.2V±1%, 2.7A, CC-CVEnd Current : 0.27A (0.02C)
Max Charging Condition29.2V±1%, 6.8A, CC-CVEnd Current : 0.27A (0.02C)
Standard Discharge Current
Max Discharge Current
Instantaneous Discharge Current
Discharge Cut-off Voltage21.0V3.0V per cell
DC-DC ConverterDC24V regulated output (Max 12A)
Battery ② Operation · Safety
Max Temperature RangeCharging: 0 – +45°C
Discharging: -20 – +55°C
Storage (recommended): +5 – +30°C
Battery Management SystemModule configuration: 1P
Overcharge cutoff: 4.20–4.25V±25mV per cell
Overcharge recovery: 4.00–4.20V±50mV per cell
Over-discharge cutoff: 2.50–2.90V±80mV per cell
Over-discharge recovery: 2.70–3.30V±100mV per cell
Overcurrent cutoff: 100A–125A±25% per module
Short-circuit protection: Yes
Over-temperature cutoff: Yes
Cell balancing: Yes
Control method: MOSFET
Storage LifeUp to 6 months under no-load conditionsState of charge: SoC 60%
Environment: ambient 25°C, humidity ≤70%
Cycle Life≥60% of nominal capacity after 700 cycles
Charge/discharge condition: standard charge, then discharge at the standard discharge current down to the cut-off voltage
Terminals · Control
Terminal configurationPositive(+) : 1P(+)
Negative(-) : 1P(-)
Terminal specificationRating: 600V, 100A (per pin)
Operating temperature range: -40°C – +85°C
Terminal fastening and wiringBolt: SCREW M6X16 nut
Thread: M6*P1.0(B5.0)
Charge/discharge switch (ON/OFF)Option: charge/discharge rocker switch (ON/OFF)