Application — Autonomous mobile robot (AMR) power

Requirement — The request was to consolidate stable long-duration operation for autonomous mobile robot (AMR) power into a single power unit.

Solution — We configured a Li-ion 7S pack (DC 25.2V, 54.4Ah) together with a charging module.

Result — A discharge configuration rated at 70A (1.3C) maximum (84A peak @ ≤1.5s), housed in approx. 8kg, completes autonomous mobile robot (AMR) power in a single pack.

If you are considering a custom build to a similar specification, submit a requirements sheet. Our engineer will review it and respond.

Specification

Specifications

Product CodeDMOP-252LI544-B70-CH20
General
ModelDMOP-252LI544-B70-CH20
DimensionApprox. L280 x W185 x h150mm (including protrusions)
Approx. L251 x W185 x h150mm (excluding protrusions)
WeightApprox. 8kg
Battery ① Electrical specifications
Battery Type
Nominal Voltage25.2V
Nominal Capacity54.4Ah
Energy
Max Discharge Power
Charging MethodCC-CV(Constant Voltage with Limited Current)
Standard Charging Condition29.4V ±1%, 11A (0.2C)(End Current : 0.05C)
Max Charging Condition29.4V ±1%, 27A (0.5C)(End Current : 0.05C)
Standard Discharge Current11A(0.2C)
Cont. Discharge Current70A(1.3C)
Peak Discharge Current84A ≤1.5sec
Discharge Cut-off Voltage21.0V3.0V per cell
Charging moduleCharging input: 24.0V(24.0V–32.0V)- Charging output: 29.4V 20A
Battery ② Operation · Safety
Operation TemperatureCharging: +10 – +45°C
Discharging: -20 – +60°C
Protection Circuit ModuleOvercharge cutoff: 4.20V ± 0.025V per cell
Overcharge recovery: 4.00V ± 0.050V per cell
Over-discharge cutoff: 2.90V ± 0.025V per cell
Over-discharge recovery: 3.30V ± 0.050V per cell
Overcurrent cutoff: 75A ± 20%
Short-circuit protection: Yes (load cutoff with auto-recovery)
Over-temperature cutoff: Yes
Active cell balancing: Yes
Storage LifeUp to 6 months under no-load conditionsState of charge: SoC 60%
Environment: ambient 25°C, humidity ≤70%
Cycle Life≥700cycle (70% DOD @ ≥60% of initial capacity)* This cycle life applies only to the standard charging NO5 and standard discharge current NO7 conditions
Terminals · Control
Terminal configuration
Terminal specification
Fastening · Wiring
Charge/discharge switch (ON/OFF)