Skip to product information
1 of 2

POWERCRAFT

Custom Battery Pack 36V 61.2Ah · 70A BMS · 5V DC-DC module

Custom Battery Pack 36V 61.2Ah · 70A BMS · 5V DC-DC module

Custom-build quote item

Product codeDMOP-360LI612-B70-CV

Pricing is quoted individually based on your requirements (voltage, capacity, peak current, enclosure, communication and so on). The button below pre-fills the RFQ form with this product's baseline specification, so you only need to edit what differs before submitting.

Start an RFQ with these specs →
contact@devicemall.co.kr · 02-982-7070 (Mon-Fri 09:00-18:00)
View full details

Application — Industrial special-equipment power

Requirement — The request was to consolidate 5V regulated auxiliary power for industrial special-equipment power into a single power unit.

Solution — We configured a Li-ion 10S pack (DC 36V, 61.2Ah) together with a 5V regulated DC-DC converter.

Result — The integrated build in an approx. 12kg housing met the industrial special-equipment power specification.

If you are considering a custom build to a similar specification, submit a requirements sheet. Our engineer will review it and respond.

Specification

Specifications

Product CodeDMOP-360LI612-B70-CV
General
ModelDMOP-360LI612-B70-CV
DimensionApprox. L287 x W285 x h145mm (including protrusions)
Approx. L260 x W285 x h145mm (excluding protrusions)
WeightApprox. 12kg
Battery ① Electrical specifications
Battery Type
Nominal Voltage36.0V
Nominal Capacity61.2Ah
Energy
Max Discharge Power
Charging MethodCC-CV(Constant Voltage with Limited Current)
Standard Charging Condition42.0V ±1%, 12A (0.2C)(End Current : 0.05C)
Max Charging Condition42.0V ±1%, 30A (0.5C)(End Current : 0.05C)
Standard Discharge Current
Max Discharge Current
Instantaneous Discharge Current
Discharge Cut-off Voltage30.0V3.0V per cell
DC-DC Converter OutputDC 24.0V, MAX 20ADC 20.0V, MAX 20ADC 5.0V, MAX 20A
Battery ② Operation · Safety
Operation TemperatureCharging: +10 – +45°C
Discharging: -20 – +60°C
Protection Circuit ModuleOvercharge cutoff: 4.25V ± 0.0250V per cell
Overcharge recovery: 4.05V ± 0.0500V per cell
Over-discharge cutoff: 2.50V ± 0.0625V per cell
Over-discharge recovery: 3.00V ± 0.1000V per cell
Overcurrent cutoff: 122A ± 20A
Short-circuit protection: Yes (load cutoff with auto-recovery)
Over-temperature cutoff: Yes
Active cell balancing: Yes
Storage LifeUp to 6 months under no-load conditionsState of charge: SoC 60%
Environment: ambient 25°C, humidity ≤70%
Cycle Life≥700cycle (70% DOD @ ≥60% of initial capacity)* This cycle life applies only under the Standard Charging NO5 and Standard Discharge Current NO7 conditions
Terminals · Control
Terminal configuration
Terminal specification
Fastening · Wiring
Charge/discharge switch (ON/OFF)