Application — Industrial special-equipment power
Requirement — The request was to consolidate 5V regulated auxiliary power for industrial special-equipment power into a single power unit.
Solution — We configured a Li-ion 10S pack (DC 36V, 61.2Ah) together with a 5V regulated DC-DC converter.
Result — The integrated build in an approx. 12kg housing met the industrial special-equipment power specification.
If you are considering a custom build to a similar specification, submit a requirements sheet. Our engineer will review it and respond.
Specification
Specifications
| Product Code | DMOP-360LI612-B70-CV |
|---|
General
| Model | DMOP-360LI612-B70-CV |
|---|---|
| Dimension | Approx. L287 x W285 x h145mm (including protrusions) Approx. L260 x W285 x h145mm (excluding protrusions) |
| Weight | Approx. 12kg |
Battery ① Electrical specifications
| Battery Type | |
|---|---|
| Nominal Voltage | 36.0V |
| Nominal Capacity | 61.2Ah |
| Energy | |
| Max Discharge Power | |
| Charging Method | CC-CV(Constant Voltage with Limited Current) |
| Standard Charging Condition | 42.0V ±1%, 12A (0.2C)(End Current : 0.05C) |
| Max Charging Condition | 42.0V ±1%, 30A (0.5C)(End Current : 0.05C) |
| Standard Discharge Current | |
| Max Discharge Current | |
| Instantaneous Discharge Current | |
| Discharge Cut-off Voltage | 30.0V3.0V per cell |
| DC-DC Converter Output | DC 24.0V, MAX 20ADC 20.0V, MAX 20ADC 5.0V, MAX 20A |
Battery ② Operation · Safety
| Operation Temperature | Charging: +10 – +45°C Discharging: -20 – +60°C |
|---|---|
| Protection Circuit Module | Overcharge cutoff: 4.25V ± 0.0250V per cell Overcharge recovery: 4.05V ± 0.0500V per cell Over-discharge cutoff: 2.50V ± 0.0625V per cell Over-discharge recovery: 3.00V ± 0.1000V per cell Overcurrent cutoff: 122A ± 20A Short-circuit protection: Yes (load cutoff with auto-recovery) Over-temperature cutoff: Yes Active cell balancing: Yes |
| Storage Life | Up to 6 months under no-load conditionsState of charge: SoC 60% Environment: ambient 25°C, humidity ≤70% |
| Cycle Life | ≥700cycle (70% DOD @ ≥60% of initial capacity)* This cycle life applies only under the Standard Charging NO5 and Standard Discharge Current NO7 conditions |
Terminals · Control
| Terminal configuration | |
|---|---|
| Terminal specification | |
| Fastening · Wiring | |
| Charge/discharge switch (ON/OFF) |