Application — Robot system power
Requirement — The customer needed a power source for robot system power with regulated auxiliary power and real-time status monitoring.
Solution — We combined a regulated DC-DC converter and CAN communication monitoring into a Li-ion 14S pack (DC 50.4V, 27Ah) as a single unit.
Result — The integrated build in an approx. 9.5kg housing met the robot system power specification.
If you are considering a custom build to a similar specification, submit a requirements sheet. Our engineer will review it and respond.
Specification
Specifications
| Product Code | DMOP-504LI270-B50-CAN-CV24 |
|---|
General
| Model | DMOP-504LI270-B50-CAN-CV24 |
|---|---|
| Dimension | Approx. L410 x W300 x h75mm (including protrusions) Approx. L380 x W300 x h75mm (excluding protrusions) |
| Weight | Approx. 9.5kg |
Battery ① Electrical specifications
| Battery Type | |
|---|---|
| Nominal Voltage | 50.4V |
| Nominal Capacity | 27.0Ah |
| Energy | |
| Max Discharge Power | |
| Charging Method | CC-CV(Constant Voltage with Limited Current) |
| Standard Charging Condition | 58.8V ±1%, 5A (0.2C)(End Current : 0.05C) |
| Max Charging Condition | 58.8V ±1%, 13A (0.5C)(End Current : 0.05C) |
| Standard Discharge Current | |
| Max Discharge Current | |
| Instantaneous Discharge Current | |
| Discharge Cut-off Voltage | 42.0V3.0V per cell |
| DC-DC Converter Output | DC 24.0V, MAX 10A |
| Communication module | CAN 2.0a(voltage, current and temperature monitoring) |
Battery ② Operation · Safety
| Operation Temperature | Charging: +10 – +45°C Discharging: -20 – +60°C |
|---|---|
| Protection Circuit Module | Overcharge cutoff: 4.20V±0.01V per cell Overcharge recovery: 4.00V±0.05V per cell Over-discharge cutoff: 2.90V±0.02V per cell Over-discharge recovery: 3.30V±0.05V per cell Overcurrent cutoff: 50A±20% Short-circuit protection: Yes (load cutoff with auto-recovery) Over-temperature cutoff: Yes Cell balancing: Yes |
| Storage Life | Up to 6 months under no-load conditionsState of charge: SoC 60% Environment: ambient 25°C, humidity ≤70% |
| Cycle Life | ≥700cycle (70% DOD @ ≥60% of initial capacity)* This cycle life applies only under the Standard Charging NO5 and Standard Discharge Current NO7 conditions |
Terminals · Control
| Terminal configuration | |
|---|---|
| Terminal specification | |
| Fastening · Wiring | |
| Charge/discharge switch (ON/OFF) |