Skip to product information
1 of 2

POWERCRAFT

Custom Battery Pack 50.4V 50Ah · 100A BMS · DC-DC module

Custom Battery Pack 50.4V 50Ah · 100A BMS · DC-DC module

Custom-build quote item

Product codeDMOP-504LI50-B100-CV

Pricing is quoted individually based on your requirements (voltage, capacity, peak current, enclosure, communication and so on). The button below pre-fills the RFQ form with this product's baseline specification, so you only need to edit what differs before submitting.

Start an RFQ with these specs →
contact@devicemall.co.kr · 02-982-7070 (Mon-Fri 09:00-18:00)
View full details

Application — Emergency power

Requirement — This emergency power application also required regulated auxiliary power.

Solution — We integrated a regulated DC-DC converter into a Li-ion 14S pack (DC 50.4V, 50Ah).

Result — A discharge configuration rated at 50A maximum (100A peak @ ≤5s), housed in approx. 15kg, completes emergency power in a single pack.

If you are considering a custom build to a similar specification, submit a requirements sheet. Our engineer will review it and respond.

Specification

Specifications

Product CodeDMOP-504LI50-B100-CV
General
ModelDMOP-504LI50-B100-CV
DimensionApprox. L420 x W195 x H145mm (including protrusions)
WeightApprox. 15kg
Battery ① Electrical specifications
Battery Type14S Li-Ion
Nominal Voltage50.4V (42.0–58.8V)
Nominal Capacity50Ah
EnergyApprox. 2520Wh
Max Discharge Power
Charging MethodCC-CV(Constant Voltage with Limited Current)
Standard Charging Condition (0.2C)58.4V±1%, 10A, CC-CVEnd Current : 1A (0.02C)
Max Charging Condition58.4V±1%, 25A, CC-CVEnd Current : 1A (0.02C)
Standard Discharge Current (0.2C)10A
Max Discharge Current50A
Instantaneous Discharge Current100A @ ≤5s
Discharge Cut-off Voltage42.0V3.0V per cell
DC-DC ConverterDC48V regulated output (Max 50A)
DC19V regulated output (Max 5A)
DC7.5V regulated output (Max 20A)
DC5V regulated output (Max 5A)
Battery ② Operation · Safety
Max Temperature RangeCharging: 0 – +45°C Discharging: -20 – +55°C Storage (recommended): +5 – +30°C
Battery Management SystemModule configuration: 2P
Overcharge cutoff: 4.20–4.25V±25mV per cell
Overcharge recovery: 4.00–4.20V±50mV per cell
Over-discharge cutoff: 2.50–2.90V±80mV per cell
Over-discharge recovery: 2.70–3.30V±100mV per cell
Overcurrent cutoff: 100A–125A±25% per module
Short-circuit protection: Yes
Over-temperature cutoff: Yes
Cell balancing: Yes
Control method: MOSFET
Storage LifeUp to 6 months under no-load conditionsState of charge: SoC 60%
Environment: ambient 25°C, humidity ≤70%
Cycle Life≥60% of nominal capacity after 500 cycles
Charge/discharge condition: standard charge, then discharge at the standard discharge current down to the cut-off voltage
Terminals · Control
Terminal configurationPositive(+) : 2P(++)
Negative(-) : 2P(--)
Terminal specificationRating: 600V, 100A (per pin)
Operating temperature range: -40°C – +85°C
Terminal fastening and wiringBolt: SCREW M6X16 nut
Thread: M6*P1.0(B5.0)
Charge/discharge switch (ON/OFF)Charge/discharge rocker switch (ON/OFF)