Application — Industrial special-equipment power

Requirement — The challenge was to handle 12V regulated auxiliary power within one pack in the industrial special-equipment power application.

Solution — We built a 12V regulated DC-DC converter into a Li-ion 14S pack (DC 50.4V, 6.8Ah).

Result — The integrated build in an approx. 4kg housing met the industrial special-equipment power specification.

If you are considering a custom build to a similar specification, submit a requirements sheet. Our engineer will review it and respond.

Specification

Specifications

Product CodeDMOP-504LI-68-B50-CV
General
ModelDMOP-504LI-68-B50-CV
DimensionApprox. L300 x W172 x h75mm (including protrusions)
Approx. L300 x W145 x h75mm (excluding protrusions)
WeightApprox. 4kg
Battery ① Electrical specifications
Battery Type
Nominal Voltage50.4V
Nominal Capacity6.8Ah
Energy
Max Discharge Power
Charging MethodCC-CV(Constant Voltage with Limited Current)
Standard Charging Condition58.8V ±1%, 1.5A (0.2C)(End Current : 0.05C)
Max Charging Condition58.8V ±1%, 3.5A (0.5C)(End Current : 0.05C)
Standard Discharge Current
Max Discharge Current
Instantaneous Discharge Current
Discharge Cut-off Voltage42.0V3.0V per cell
DC-DC Converter OutputDC 48.0V, MAX 10ADC 12.0V, MAX 10A
Battery ② Operation · Safety
Operation TemperatureCharging: +10 – +45°C
Discharging: -20 – +60°C
Protection Circuit ModuleOvercharge cutoff: 4.20V±0.01V per cell
Overcharge recovery: 4.00V±0.05V per cell
Over-discharge cutoff: 2.90V±0.02V per cell
Over-discharge recovery: 3.30V±0.05V per cell
Overcurrent cutoff: 50A±20%
Short-circuit protection: Yes (load cutoff with auto-recovery)
Over-temperature cutoff: Yes
Cell balancing: Yes
Storage LifeUp to 6 months under no-load conditionsState of charge: SoC 60%
Environment: ambient 25°C, humidity ≤70%
Cycle Life≥700cycle (70% DOD @ ≥60% of initial capacity)* This cycle life applies only under the Standard Charging NO5 and Standard Discharge Current NO7 conditions