Application — Industrial special-equipment power
Requirement — The customer needed a power source for industrial special-equipment power with regulated auxiliary power and real-time status monitoring.
Solution — We combined a charging module, a regulated DC-DC converter, and CAN communication monitoring into a Li-ion 14S pack (DC 50.4V, 7.5Ah) as a single unit.
Result — A discharge configuration rated at 15A maximum (30A peak @ ≤1.5s), housed in approx. 5kg, completes industrial special-equipment power in a single pack.
If you are considering a custom build to a similar specification, submit a requirements sheet. Our engineer will review it and respond.
Specification
Specifications
| Product Code | DMOP-504LI75-B50-CAN-PDC4 |
|---|
General
| Model | DMOP-504LI75-B50-CAN-PDC4 |
|---|---|
| Dimension | Approx. L290 x W359.3 x H75mm (including protrusions) |
| Weight | Approx. 5kg |
Battery ① Electrical specifications
| Battery Type | 14S Li-ion |
|---|---|
| Nominal Voltage | 50.4V (42.0–58.8V) |
| Nominal Capacity | 7.5Ah |
| Energy | 378Wh |
| Max Discharge Power | 756W |
| Charging Method | CC-CV(Constant Voltage with Limited Current) |
| Standard Charging Condition (0.2C) | 58.4V±1%, 1.5A, CC-CVEnd Current : 0.15A (0.02C) |
| Max Charging Condition | 58.4V±1%, 4A, CC-CVEnd Current : 0.15A (0.02C) |
| Standard Discharge Current (0.2C) | 1.5A |
| Max Discharge Current | 15A |
| Instantaneous Discharge Current | 30A @ ≤1.5s |
| Discharge Cut-off Voltage | 42.0V3.0V per cell |
| Communication module (CAN 2.0a) | Option (CAN): voltage, current, temperature and state of charge monitoring |
| DC Charge Module | IN : DC36–60V, MAX 10AOUT : DC58.4V, 4A (CC-CV) |
Battery ② Operation · Safety
| Max Temperature Range | Charging: 0 – +45°C Discharging: -20 – +55°C Storage (recommended): +5 – +30°C |
|---|---|
| Battery Management System | Module configuration: 1P Overcharge cutoff: 4.20–4.25V±25mV per cell Overcharge recovery: 4.00–4.20V±50mV per cell Over-discharge cutoff: 2.50–2.90V±80mV per cell Over-discharge recovery: 2.70–3.30V±100mV per cell Overcurrent cutoff: 100A–125A±25% per module Short-circuit protection: Yes Over-temperature cutoff: Yes Cell balancing: Yes Control method: MOSFET |
| Storage Life | Up to 6 months under no-load conditionsState of charge: SoC 60% Environment: ambient 25°C, humidity ≤70% |
| Cycle Life | ≥60% of nominal capacity after 500 cycles Charge/discharge condition: standard charge, then discharge at the standard discharge current down to the cut-off voltage Environment: ambient 25°C, humidity ≤70% |
Terminals · Control
| Terminal configuration | DISCHARGEPositive(+) : 1P(+) Negative(-) : 2P(-) CHARGEPositive(+) : 1P(+) Negative(-) : 1P(-) |
|---|---|
| Terminal specification | Rating: 600V, 100A (per pin) Operating temperature range: -40°C – +85°C |
| Terminal fastening and wiring | Bolt: SCREW M6X16 nut Thread: M6*P1.0(B5.0) Recommended tightening torque: 12kgf·cm |
| Charge/discharge switch (ON/OFF) | Option: charge/discharge rocker switch (ON/OFF) |