Application — Industrial special-equipment power
Requirement — The customer needed a power source for industrial special-equipment power with high-output discharge, 12V and 5V regulated auxiliary power and real-time status monitoring.
Solution — We combined 12V and 5V regulated DC-DC converters and CAN communication monitoring into a LiFePO4 16S pack (DC 51.2V, 230.4Ah) as a single unit.
Result — Three simultaneous outputs — a main DC 51.2V rail at up to 250A (750A peak @ ≤5s) plus regulated 12V 100A and 5V 20A outputs — housed in approx. 130kg, complete industrial special-equipment power in a single pack.
If you are considering a custom build to a similar specification, submit a requirements sheet. Our engineer will review it and respond.
Specification
Specifications
| Product Code | DMOP-512LF2304-B900-CV |
|---|
General
| Model | DMOP-512LF2304-B900-CV |
|---|---|
| Dimension | Approx. L1,080 x W390 x H227mm (including protrusions) Approx. L1,080 x W350 x H227mm (excluding protrusions) |
| Weight | Approx. 130kg |
Battery ① Electrical specifications
| Battery Type | 16S LiFePO₄ |
|---|---|
| Nominal Voltage | 51.2V (44.8–58.4V) |
| Nominal Capacity | 230.4Ah |
| Energy | Approx. 11,796.48Wh |
| Max Discharge Power | Main – DC 51.2V, 12,800W Converter (regulated) 1 – DC5V, 100W Converter (regulated) 2 – DC12V, 1,200W |
| Charging Method | CC-CV(Constant Voltage with Limited Current) |
| Standard Charging Condition (0.2C) | 58.4V±1%, 25A, CC-CVEnd Current : 4A (0.02C) |
| Max Charging Condition | 58.4V±1%, 45A, CC-CVEnd Current : 4A (0.02C) |
| Standard Discharge Current | |
| Max Discharge Current | Main – DC 51.2V, 250A Converter (regulated) 1 – DC5V, 20A Converter (regulated) 2 – DC12V, 100A |
| Instantaneous Discharge Current | Main – 750A @ ≤5s |
| Discharge Cut-off Voltage | 44.8V2.8V per cell |
| Monitoring | Option (CAN): voltage, current, state of charge and temperature monitoring |
Battery ② Operation · Safety
| Max Temperature Range | Charging: 0 – +45°C Discharging: -20 – +55°C Storage (recommended): +5 – +30°C |
|---|---|
| Battery Management System | Module configuration: 18P Overcharge cutoff: 3.70V±25mV per cell Overcharge recovery: 3.50V±50mV per cell Over-discharge cutoff: 2.50V±25mV per cell Over-discharge recovery: 2.70V±50mV per cell Overcurrent cutoff: 110±20% per module Short-circuit protection: Yes Over-temperature cutoff: Yes Cell balancing: Yes Control method: MOSFET |
| Storage Life | Up to 6 months under no-load conditionsState of charge: SoC 60% Environment: ambient 25°C, humidity ≤70% |
| Cycle Life | ≥60% of nominal capacity after 2,500 cycles Charge/discharge condition: standard charge, then discharge at the standard discharge current down to the cut-off voltage Environment: ambient 25°C, humidity ≤70% |