Application — AGV and material-handling equipment power
Requirement — This AGV and material-handling equipment power application also required high-output discharge, AC220V mains power, and regulated auxiliary power.
Solution — We integrated an AC220V 5kW inverter and a regulated DC-DC converter into a LiFePO4 16S pack (DC 51.2V, 5,242Wh).
Result — The integrated build in an approx. 80kg housing met the AGV and material-handling equipment power specification.
If you are considering a custom build to a similar specification, submit a requirements sheet. Our engineer will review it and respond.
Specification
Specifications
| Product Code | DMOP-LF5242Wh-AC5000W-DC512 |
|---|
General
| Model | DMOP-LF5242Wh-AC5000W-DC512 |
|---|---|
| Dimension | Approx. L542.5x W669.3.5 x H153mm(including protrusions) |
| Weight | Approx. 80kg |
Battery ① Electrical specifications
| Battery Type | 16S LiFePO₄ |
|---|---|
| Nominal Voltage | 51.2V (44.8–58.4V) |
| Nominal Capacity | |
| Energy | Approx. 5,242Wh |
| Max Discharge Power | |
| Charging Method | CC-CV(Constant Voltage with Limited Current) |
| Standard Charging Condition (0.2C) | 58.4V±1%, 20.48A, CC-CVEnd Current : 2.048A (0.02C) |
| Max Charging Condition | 58.4V±1%, 51.2A, CC-CVEnd Current : 2.048A (0.02C) |
| Standard Discharge Current | |
| Max Discharge Current | |
| Instantaneous Discharge Current | |
| Discharge Cut-off Voltage | 44.8V2.8V per cell |
| Max Discharge Power | AC : AC 220V, 5,000W (60Hz), (Surge 6,000W ≤1.5Sec) - DC : DC 51.2V (SOC 0-100% : 44.8 – 58.4V) Max ≤100A, (Peak 300A ≤5 sec |
Battery ② Operation · Safety
| Max Temperature Range | Charging: 0 – +45°C Discharging: -20 – +55°C Storage (recommended): +5 – +30°C |
|---|---|
| Battery Management System | Module configuration: 8P Overcharge cutoff: 3.70V±25mV per cell Overcharge recovery: 3.50V±50mV per cell Over-discharge cutoff: 2.50V±25mV per cell Over-discharge recovery: 2.70V±50mV per cell Overcurrent cutoff: 110±20% per module Short-circuit protection: Yes Over-temperature cutoff: Yes Cell balancing: Yes Control method: MOSFET |
| Storage Life | Up to 6 months under no-load conditionsState of charge: SoC 60% Environment: ambient 25°C, humidity ≤70% |
| Cycle Life | ≥60% of nominal capacity after 2,500 cycles Charge/discharge condition: standard charge, then discharge at the standard discharge current down to the cut-off voltage Environment: ambient 25°C, humidity ≤70% |
Terminals · Control
| Terminal configuration | |
|---|---|
| Terminal specification | |
| Fastening · Wiring | |
| Charge/discharge switch (ON/OFF) | AC switch DC switch *Note: when operating on AC, the DC switch must be ON |