Application — AC220V portable emergency power

Requirement — A portable emergency power unit was needed to immediately replace utility AC power during outages and at outdoor sites.

Solution — We built an AC220V 3kW (60Hz) inverter and a regulated (DC 12V) converter into a 3,024Wh pack so that standard outlets can be used as they are. Status is checked over RS485 communication.

Result — In a 29kg portable form factor it supplies AC220V 3kW (4kW peak) and provides instant-transfer backup in the event of an outage.

If you are considering a custom build to a similar specification, submit a requirements sheet. Our engineer will review it and respond.

Specification

Specifications

Product CodeDMOP-LI3024Wh-AC3000-DC252
General
ModelDMOP-LI3024Wh-AC3000-DC252
DimensionL473 × W500 × H159 mm
Weight29 kg
Battery ① Electrical specifications
Battery Type7S Li-Ion
Nominal VoltageDC 25.2 V21.0 – 29.4 V
Nominal Capacity
Energy3,024 Wh
Max Discharge PowerAC220V 3 kW60Hz · Surge 4kW ≤ 1.5s
Charging MethodCC-CV(Constant Voltage with Limited Current)
Standard Charging Condition (0.2C)29.2V±1%, 24A, CC-CVEnd Current : 2.4A (0.02C)
Max Charging Condition29.2V±1%, 50A, CC-CVEnd Current : 2.4A (0.02C)
Standard Discharge Current (0.5C)
Max Discharge Current100 A
Instantaneous Discharge Current150 APeak ≤ 1.5s
Cut-off21.0 V
AC outputAC 220V – 3,000W(60Hz) (Surge 4,000W ≤ 1.5Sec)
DC outputDC 25.2V(SOC 0-100% : DC 21.0 – 29.4V) max ≤100A, (Peak 150A ≤1.5 sec)
Communication moduleRS 485 (voltage, current, temperature and state of charge monitoring)
Battery ② Operation · Safety
Temperature rangeCharging: 0 – +45°C
Discharging: -20 – +55°C
Storage (recommended): +5 – +30°C
BMSModule configuration: 4P
Overcharge cutoff: 4.20–4.25V±25mV per cell
Overcharge recovery: 4.00–4.20V±50mV per cell
Over-discharge cutoff: 2.50–2.90V±80mV per cell
Over-discharge recovery: 2.70–3.30V±100mV per cell
Overcurrent cutoff: 100A–125A±25% per module
Short-circuit protection: Yes
Over-temperature cutoff: Yes
Cell balancing: Yes
Control method: MOSFET
Storage LifeUp to 6 months under no-load conditionsState of charge: SOC 50%
Environment: ambient 25°C, humidity ≤70%
Cycle Life≥60% of nominal capacity after 500 cycles
Charge/discharge condition: standard charge, then discharge at the standard discharge current down to the cut-off voltage
Environment: ambient 25°C, humidity ≤70%
Terminals · Control
Terminal configuration
Terminal specification
Fastening · Wiring