Skip to product information
1 of 2

POWERCRAFT

Custom Power Supply Unit 25.6V 2,457Wh · AC220V 2kW inverter · RS485 communication

Custom Power Supply Unit 25.6V 2,457Wh · AC220V 2kW inverter · RS485 communication

Custom-build quote item

Product codeDMOP-LF2457Wh-AC2000W

Pricing is quoted individually based on your requirements (voltage, capacity, peak current, enclosure, communication and so on). The button below pre-fills the RFQ form with this product's baseline specification, so you only need to edit what differs before submitting.

Start an RFQ with these specs →
contact@devicemall.co.kr · 02-982-7070 (Mon-Fri 09:00-18:00)
View full details

Application — AGV and material-handling equipment power

Requirement — The customer needed a power source for AGV and material-handling equipment power with AC220V mains power and real-time status monitoring.

Solution — We combined an AC220V 2kW inverter and RS485 communication monitoring into a LiFePO4 8S pack (DC 25.6V, 2,457Wh) as a single unit.

Result — The integrated build in an approx. 33kg housing met the AGV and material-handling equipment power specification.

If you are considering a custom build to a similar specification, submit a requirements sheet. Our engineer will review it and respond.

Specification

Specifications

Product CodeDMOP-LF2457Wh-AC2000W
General
ModelDMOP-LF2457Wh-AC2000W
DimensionApprox. L542 x W300 x H247mm (including protrusions)
WeightApprox. 33kg
Battery ① Electrical specifications
Battery Type8S LiFePO4
Nominal Voltage25.6V (22.4–29.2V)
Nominal Capacity
Energy2,457Wh
Max Discharge Power2,000W
Charging MethodCC-CV(Constant Voltage with Limited Current)
Standard Charging Condition (0.2C)29.2V±1%, 20A, CC-CVEnd Current : 2A (0.02C)
Max Charging Condition29.2V±1%, 50A, CC-CVEnd Current : 2A (0.02C)
Standard Discharge Current
Max Discharge Current
Instantaneous Discharge Current
Discharge Cut-off Voltage22.4V2.8V per cell
AC outputAC 220V – 2,000W(60Hz) (Surge 2,500W ≤ 3Sec)
Communication module (RS 485)Option: voltage, current, temperature and state of charge monitoring
Battery ② Operation · Safety
Max Temperature RangeCharging: 0 – +45°C Discharging: -20 – +55°C Storage (recommended): +5 – +30°C
Battery Management SystemModule configuration: 4P
Overcharge cutoff: 3.70–3.90V±25mV per cell
Overcharge recovery: 3.50–3.70V±50mV per cell
Over-discharge cutoff: 2.00–2.50V±25mV per cell
Over-discharge recovery: 2.40–2.90V±50mV per cell
Overcurrent cutoff: 105A–130A±25% per module
Short-circuit protection: Yes
Over-temperature cutoff: Yes
Cell balancing: Yes
Control method: MOSFET
Storage LifeUp to 6 months under no-load conditionsState of charge: SoC 60%
Environment: ambient 25°C, humidity ≤70%
Cycle Life≥60% of nominal capacity after 2,500 cycles
Charge/discharge condition: standard charge, then discharge at the standard discharge current down to the cut-off voltage
Environment: ambient 25°C, humidity ≤70%
Terminals · Control
Terminal configuration
Terminal specification
Fastening · Wiring
Charge/discharge switch (ON/OFF)Option: charge/discharge rocker switch (ON/OFF)