Custom Power Supply Unit 50.4V 13,600Wh · AC220V 2kW inverter

Custom Power Supply Unit 50.4V 13,600Wh · AC220V 2kW inverter

Custom-build quote item

Product codeDMOP-13600Wh-AC2000

Pricing is quoted individually based on your requirements (voltage, capacity, peak current, enclosure, communication and so on). The button below pre-fills the RFQ form with this product's baseline specification, so you only need to edit what differs before submitting.

Start an RFQ with these specs →
contact@devicemall.co.kr · 02-982-7070 (Mon-Fri 09:00-18:00)
View full details

Application — ESS and high-capacity power supply

Requirement — The request was to consolidate AC220V mains power for ESS and high-capacity power supply into a single power unit.

Solution — We configured a Li-ion 14S pack (DC 50.4V, 13,600Wh) together with an AC220V 2kW inverter.

Result — The integrated build in an approx. 75kg housing met the ESS and high-capacity power supply specification.

If you are considering a custom build to a similar specification, submit a requirements sheet. Our engineer will review it and respond.

Specification

Specifications

Product CodeDMOP-13600Wh-AC2000
General
ModelDMOP-13600Wh-AC2000
DimensionApprox. L412.5 x W700 x H232mm (including protrusions)
WeightApprox. 75kg
Battery ① Electrical specifications
Battery TypeLi-ion
Nominal Voltage50.4V (42.0–58.8V)
Nominal Capacity
Energy13,600Wh
Max Discharge Power2,000W
Charging MethodCC-CV(Constant Voltage with Limited Current)
Standard Charging Condition
Max Charging Condition58.4V±1%, 25A, CC-CVEnd Current : 5.4A (0.02C)
Standard Discharge Current
Max Discharge Current
Instantaneous Discharge Current
Discharge Cut-off Voltage42.0V3.0V per cell
AC outputAC 220V – 2,000W(60Hz)
Battery ② Operation · Safety
Max Temperature RangeCharging: 0 – +45°C Discharging: -20 – +55°C Storage (recommended): +5 – +30°C
Battery Management SystemModule configuration: 6P
Overcharge cutoff: 4.20–4.25V±25mV per cell
Overcharge recovery: 4.00–4.20V±50mV per cell
Over-discharge cutoff: 2.50–2.90V±80mV per cell
Over-discharge recovery: 2.70–3.30V±100mV per cell
Overcurrent cutoff: 100A–125A±25% per module
Short-circuit protection: Yes
Over-temperature cutoff: Yes
Cell balancing: Yes
Control method: MOSFET
Storage LifeUp to 6 months under no-load conditionsState of charge: SoC 60%
Environment: ambient 25°C, humidity ≤70%
Cycle Life≥60% of nominal capacity after 700 cycles
Charge/discharge condition: standard charge, then discharge at the standard discharge current down to the cut-off voltage
Environment: ambient 25°C, humidity ≤70%
Terminals · Control
Terminal configuration
Terminal specification
Fastening · Wiring
Charge/discharge switch (ON/OFF)Option: charge/discharge rocker switch (ON/OFF)