Skip to product information
1 of 2

POWERCRAFT

Custom Power Supply Unit 50.4V 3,628Wh · AC220V 2kW inverter · 48V DC-DC module

Custom Power Supply Unit 50.4V 3,628Wh · AC220V 2kW inverter · 48V DC-DC module

Custom-build quote item

Product codeDMOP-3628Wh-AC2000-DC504

Pricing is quoted individually based on your requirements (voltage, capacity, peak current, enclosure, communication and so on). The button below pre-fills the RFQ form with this product's baseline specification, so you only need to edit what differs before submitting.

Start an RFQ with these specs →
contact@devicemall.co.kr · 02-982-7070 (Mon-Fri 09:00-18:00)
View full details

Application — Industrial special-equipment power

Requirement — The challenge was to handle AC220V mains power and 48V regulated auxiliary power within one pack in the industrial special-equipment power application.

Solution — We built an AC220V 2kW inverter and a 48V regulated DC-DC converter into a Li-ion 14S pack (DC 50.4V, 3,628Wh).

Result — The integrated build in an approx. 28kg housing met the industrial special-equipment power specification.

If you are considering a custom build to a similar specification, submit a requirements sheet. Our engineer will review it and respond.

Specification

Specifications

Product CodeDMOP-3628Wh-AC2000-DC504
General
ModelDMOP-3628Wh-AC2000-DC504
DimensionApprox. L410 x W554 x H145mm (including protrusions)
WeightApprox. 28kg
Battery ① Electrical specifications
Battery Type14S Li-Ion
Nominal Voltage50.4V (42.0–58.8V)
Nominal Capacity
Energy3,628Wh
Max Discharge Power2,000W
Charging MethodCC-CV(Constant Voltage with Limited Current)
Standard Charging Condition (0.2C)58.4V±1%, 14.4A, CC-CVEnd Current : 1.44A (0.02C)
Max Charging Condition58.4V±1%, 36A, CC-CVEnd Current : 1.44A (0.02C)
Standard Discharge Current
Max Discharge Current
Instantaneous Discharge Current
Discharge Cut-off Voltage42.0V3.0V per cell
AC outputAC 220V – 2,000W(60Hz) (Surge 2,500W ≤ 3Sec)
DC outputDC 50.4V ≤70A (Peak 200A ≤ 5Sec)
Battery ② Operation · Safety
Max Temperature RangeCharging: 0 – +45°C Discharging: -20 – +55°C Storage (recommended): +5 – +30°C
Battery Management SystemModule configuration: 4P
Overcharge cutoff: 4.20–4.25V±25mV per cell
Overcharge recovery: 4.00–4.20V±50mV per cell
Over-discharge cutoff: 2.50–2.90V±80mV per cell
Over-discharge recovery: 2.70–3.30V±100mV per cell
Overcurrent cutoff: 100A–125A±25% per module
Short-circuit protection: Yes
Over-temperature cutoff: Yes
Cell balancing: Yes
Control method: MOSFET
Storage LifeUp to 6 months under no-load conditionsState of charge: SoC 60%
Environment: ambient 25°C, humidity ≤70%
Cycle Life≥60% of nominal capacity after 500 cycles
Charge/discharge condition: standard charge, then discharge at the standard discharge current down to the cut-off voltage
Environment: ambient 25°C, humidity ≤70%
Terminals · Control
Terminal configuration
Terminal specification
Fastening · Wiring
Charge/discharge switch (ON/OFF)Option: AC / DC charge/discharge rocker switch (ON/OFF)