Application — ESS and high-capacity power supply
Requirement — The request was to consolidate AC220V mains power, recharging while driving and 5V·12V regulated auxiliary power for ESS and high-capacity power supply into a single power unit.
Solution — We configured a Li-ion 14S pack (DC 50.4V, 30.2kWh) together with an AC220V 6kW inverter, an onboard charging module and 5V·12V regulated DC-DC converters.
Result — The integrated build in an approx. 180kg housing met the ESS and high-capacity power supply specification.
If you are considering a custom build to a similar specification, submit a requirements sheet. Our engineer will review it and respond.
Specification
Specifications
| Product Code | DMOP-LI30240Wh-AC4000-CV-C20 |
|---|
General
| Model | DMOP-LI30240Wh-AC4000-CV-C20 |
|---|---|
| Dimension | Approx. L833 x W1,141 x H157.7mm (including protrusions) |
| Weight | Approx. 180kg |
Battery ① Electrical specifications
| Battery Type | 14S Li-ion |
|---|---|
| Nominal Voltage | 50.4V (42.0–58.8V) |
| Nominal Capacity | |
| Energy | 30,240Wh |
| Max Discharge Power | |
| Charging Method | CC-CV(Constant Voltage with Limited Current) |
| Standard Charging Condition (0.2C) | 58.4V±1%, 50A, CC-CVEnd Current : 12A (0.02C) |
| Max Charging Condition | 58.4V±1%, 100A, CC-CVEnd Current : 12A (0.02C) |
| Standard Discharge Current | |
| Max Discharge Current | |
| Instantaneous Discharge Current | |
| Discharge Cut-off Voltage | 42.0V3.0V per cell |
| AC output | AC 220V – 4,000W(60Hz) (Surge 5,000W ≤ 1.5Sec) |
| DC-DC Converter OUTPUT | DC5V regulated output (Max 50A) DC12V regulated output (Max 100A) |
| Alternator charging module | Charging input: DC 12.3V – 32.0V Charging output: DC 58.4V 20A MAX (CC-CV) |
Battery ② Operation · Safety
| Max Temperature Range | Charging: 0 – +45°C Discharging: -20 – +55°C Storage (recommended): +5 – +30°C |
|---|---|
| Battery Management System | Module configuration: 12P Overcharge cutoff: 4.20–4.25V±25mV per cell Overcharge recovery: 4.00–4.20V±50mV per cell Over-discharge cutoff: 2.50–2.90V±80mV per cell Over-discharge recovery: 2.70–3.30V±100mV per cell Overcurrent cutoff: 100A–125A±25% per module Short-circuit protection: Yes Over-temperature cutoff: Yes Cell balancing: Yes Control method: MOSFET |
| Storage Life | Up to 6 months under no-load conditionsState of charge: SoC 60% Environment: ambient 25°C, humidity ≤70% |
| Cycle Life | ≥60% of nominal capacity after 500 cycles Charge/discharge condition: standard charge, then discharge at the standard discharge current down to the cut-off voltage Environment: ambient 25°C, humidity ≤70% |
Terminals · Control
| Terminal configuration | |
|---|---|
| Terminal specification | |
| Fastening · Wiring | |